USP 797 vs. 795 Compounding Compared

USP 797 (sterile) vs. USP 795 (nonsterile) compounding compared: environment, CSP categories, personnel testing, documentation, and beyond-use dating.

Written and maintained by CASRAI Editorial Board

Last updated

Ask CASRAI · included with Regulatory Radar

Ask about USP 797 vs. 795 Compounding Compared

Ask CASRAI answers research-administration questions and cites the passages behind every claim — and says so when the corpus does not cover something, instead of guessing. It comes with a Regulatory Radar subscription at $29 a month, alongside the daily digest of regulatory changes and the dashboard of what changed.

150 questions a day, on this site, over the API, or inside your own tools through the CASRAI MCP server.

Everything CASRAI publishes — this page, the dictionary, the guides and the news — stays free to read, with no account and no card.

How do USP 797, USP 795 compare side by side?

The table below compares USP 797, USP 795 across 8 procurement-relevant dimensions, from what it governs through typical settings.

Side-by-side comparison

DimensionUSP 797USP 795
What it governsCompounding a preparation that must be sterile at administration (IV admixtures, TPN, injectables, ophthalmic, intrathecal)Compounding a preparation that is not required to be sterile (most oral liquids, capsules, tablets, topical creams/ointments, suppositories)
Current official versionPublished USP-NF 2023 Issue 1 (Nov 1, 2022); official since November 1, 2023Published USP-NF 2023 Issue 1 (Nov 1, 2022); official since November 1, 2023 — first major revision since 2014
Compounding environmentCategory 1: unclassified Segregated Compounding Area (SCA) with ISO Class 5 primary engineering control. Category 2: classified cleanroom suite (ISO Class 7 buffer room + ISO Class 8 or better anteroom). Category 3: full Category 2 facility plus additional testing.A designated, suitably clean and organized compounding area with equipment appropriate to the preparations compounded — no ISO-classified cleanroom or sterile primary engineering control required.
Personnel competency testingGarbing/hand-hygiene observation, gloved fingertip sampling, and media-fill testing, at intervals that vary by CSP category (verify exact interval against the current chapter)Hand hygiene, garbing appropriate to nonsterile work, and technique-specific competency evaluation — no gloved fingertip sampling or media-fill testing, since there is no sterility claim to verify
Key documentationMaster formulation record, compounding record, CSP category assignment, environmental monitoring records, PEC/room certification recordsMaster formulation record and compounding record; documentation of any stability data relied on for beyond-use dating
Beyond-use date (BUD) basisPrimarily the CSP Category (reflecting the verified level of environmental control), plus storage condition, dosage form, and any sterility/stability testing or applicable stability data — see the current chapter's BUD tables for exact allowable periods.Primarily whether the formulation is aqueous or nonaqueous, the dosage form/packaging, storage condition, and whether supporting stability data exists — the chapter provides conservative default BUDs where no stability data is available.
Interaction with USP 800If the drug is a NIOSH-listed hazardous drug and must be compounded sterile, 797 and 800 both apply — 800 layers additional containment engineering controls on top of 797's sterile-compounding requirements.If the drug is a NIOSH-listed hazardous drug and is compounded nonsterile, 795 and 800 both apply — 800 layers additional containment requirements on top of 795's nonsterile compounding requirements.
Typical settingsHospital IV/TPN rooms, outpatient infusion pharmacies, 503A/503B sterile compounding facilities, investigational drug servicesCommunity and hospital outpatient pharmacies compounding oral/topical preparations, veterinary compounding, 503A nonsterile compounding facilities

Common questions

Common questions about USP 797 vs USP 795

How do I know if a preparation falls under USP 797 or USP 795?

+

The determining factor is whether the finished preparation must be sterile at the point of administration, not how complicated the compounding process is. An injectable, IV admixture, or ophthalmic/intrathecal preparation falls under 797 regardless of how simple the compounding steps are; an oral, topical, or other route that does not require sterility falls under 795, even if the formulation itself is complex.

Can a single pharmacy be subject to both chapters?

+

Yes. Many hospital and community pharmacies compound both sterile and nonsterile preparations and have to satisfy 797's requirements for the sterile work and 795's requirements for the nonsterile work as separate, parallel compliance obligations — they are not alternatives to choose between.

Are USP 797 and 795 federally mandatory?

+

Neither chapter is a self-executing federal statute. Both become enforceable mainly through state board of pharmacy regulations that incorporate the current USP-NF, and through accreditation surveys that reference it. Adoption language and enforcement timing vary by state, so confirm the specific rules of each state a pharmacy is licensed under.

Does USP 800 replace 797 or 795?

+

No. USP 800 governs facility engineering controls for hazardous drugs specifically, and applies alongside whichever of 797 or 795 fits the preparation's sterility requirement — it adds containment requirements rather than substituting for either chapter.

Referenced across the research world

University of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logoUniversity of Cambridge logoColumbia University logoCrossref logoUniversity of Edinburgh logoHarvard University logoUniversity of Oxford logoPrinceton University logoStanford School of Medicine logoUniversity College London logoORCID logo
  • University of Cambridge logo
  • Columbia University logo
  • Crossref logo
  • University of Edinburgh logo
  • Harvard University logo
  • University of Oxford logo
  • Princeton University logo
  • Stanford School of Medicine logo
  • University College London logo
  • ORCID logo

View CASRAI adoption →

Regulatory Radar

Stop finding out after the fact

$29/month, cancel anytime. Daily digest updates from our analysis, a dashboard holding the same items, and a cited assistant for everything they raise.

  • Federal Register, Federal Register+, Grants.gov, Regulations.gov, NSF News, UKRI, plus CASRAI’s own published content.
  • 72,264 indexed passages, and every answer cites the ones it drew on.